STERILWAVE 250
With a waste treatment capacity of 50 kg per hour, the Sterilwave 250 allows medium-sized institutions to treat their biomedical waste, guaranteeing safety and traceability at greatly reduced operating costs.
WASTE DECONTAMINATION
ON-SITE TREATMENT OF BIOMEDICAL WASTE
Download Brochure
View Product Pictures
The Sterilwave 250 has the same approvals as the SW 440 machine used in the UK/NHS for over 8 years and complies with the strictest environmental and bacteriological reduction standards. It allows institutions to treat up to 500L of biomedical waste per hour (50kg/hr*) in complete safety.
Its innovative concept uses rotating grinder blades to grind down all types of waste, including metallic objects. Biohzardous waste is sterilised using microwaves and converted into inert municipal waste, reducing its volume by more than 80% and its weight by 25%. Its environmental impact and operating costs are reduced while ensuring the safety of the operator. As it uses microwave technology, and the vessel is maintained a a very slight negative pressure, Sterilwave technology does not require a separate high pressure steam boiler on site, so there is no risk from excess pressure and no hazardous liquid effluent is produced. Its easy installation requires only 12m² of space per unit for safe treatment of large quantities of ‘on site’ biomedical waste.
RANGE OF EXPERTISE
REASONS TO CHOOSE STERILWAVE 250
Effective
Bacterial inactivation higher than international regulatory standards (up to 8log10)
Economical
Robust equipment – Quick return on investment – No more storage, easy to maintain – Most competitive operating cost on the market.
Environmentally-friendly
No environmental impact – On-site treatment – No transportation – No liquid effluent.
Plug & Play
Ready-to-use system which requires no specific technical qualifications
Safe
Technology combining shredding & microwave sterilization in one single vessel – No pressurisation unlike in an autoclave.
WASTE DECONTAMINATION
ON-SITE TREATMENT OF BIOMEDICAL WASTE
Datasheet
Waste capacity
500L/h
Up to 50 kg/h
(with a density of 1L = 0.1kg)
Vessel capacity
250 L
Average cycle time
30′
Dimensions (L x W x D)
1,6 x 1,1 x 1,5 m
Weight
1200 kg
Working area
15 sq.m (Full workflow area)
Ceiling height: 2.2m
Electricity
400V/ 3-Phase, 63A
Technology
Grinding by rotating blades and heating by microwaves
Operating Data
Microbial inactivation
Spore up to 8log10 Virus up to 6log10 STAATT requirements and NFX30-503 compliant
Volume reduction
Up to 85%
Weight Reduction
Up to 25%
Final Waste
Unrecognisable, inert, dry, stable
Loading Process
Manual or Automatic (Option)
Process Management
Full traceability
Benefits
Full decontamination
Biohazardous waste is sterilised with microwaves (heat it up to 110°C for 20 minutes) and allows microbial inactivation of up to 8log10.
Safe processing
Microwave sterilisation technology does not require pressurisation, and this removes any risk of explosion. Moreover, the microwaves are confined to the inside of the vessel to avoid operator exposure to radiation.
No liquid effluent
The treatment process does not produce any steam or liquid effluent, which means no consumption of water and no need to include an effluent drainage system in its installation.
No segregation
The Sterilwave is suitable for all types of biomedical waste (needles, glass, solids, liquids, etc.)
Easy maintenance
The equipment is built using robust technology. IP connection for diagnostics. Preventive maintenance plan/calendar with alarm.
Reduces weight by 25% and volume by 85%
Biomedical waste is converted to inert waste similar to municipal waste. The dry ground-up waste can also be used as secondary fuel.
Technology
With its automated grinding and microwave sterilisation process contained in a single vessel, the Sterilwave can produce bacterial inactivation (higher than 8log10) of biomedical waste in less than 30 minutes, in complete safety and without intermediate handling. Unlike autoclave technologies, our system does not require the vessel to be pressurised. The Sterilwave converts biomedical waste into dry waste which is inert and completely disinfected, reducing its weight by more than 25% and its volume by 85%. The end product is similar to municipal waste and can then be fed into standard urban waste systems.
Treats clinical waste on producer site. Highly Efficient . Cost Effective . Safe . UK and International Safety Record. Compliant. Reduced CO2 footprint and HGV traffic. Effective.